{"product_id":"schneider-electric-tesys-d-tesys-d-leistungsschutz-24-v-dc-spule-3-polig-300-v-ac-690-v-dc-12-a-7-5-kw","title":"Schneider Electric TeSys D Contactor, 24V dc Coil, 3-Pole, 12 A, 7.5 kW 24V dc, 3 NO, 690 V dc, 300V ac","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\u003cp\u003eProduct Type = Contactor\u003cbr\u003eNumber of Poles = 3\u003cbr\u003eContact Voltage = 690, 300V dc\u003cbr\u003eContact Current = 12A\u003cbr\u003eSeries = TeSys DkW\u003cbr\u003eMount Type = DIN Rail\u003cbr\u003eNormal State Configuration = 3 NO\u003cbr\u003eNumber of Auxiliary Contacts = 2\u003cbr\u003eTerminal Type = Cage Clamp\u003cbr\u003eContactor Application = Motor ControlA\u003cbr\u003eMaximum Operating Temperature = 60°C\u003cbr\u003eLength = 45mm\u003cbr\u003eBetter World Product = Yes\u003cbr\u003ePole and Throw Configuration = 3\u003cbr\u003e\u003cbr\u003eSchneider Electric TeSys D Contactor - LC1D123BD TeSys Contactors from Schneider Electric combine long mechanical and electrical life to offer a highly reliable contactor. The TeSys contactors offer quick simple setup while maintaining compliance with international standards. Features and Benefits • Typically, applications include resistive loads and motor control • Highly reliable • Excellent quality • Easily installed accessories • Predominantly used to motor control and resistive loads • Holds a utilisation category of AC-3, AC-4 and AC-1 • 3 poles with 3 NO power pole contact composition • The rated operational voltage is Power circuit: \u0026lt;= 690 V AC 25..400 Hz and Power circuit: \u0026lt;= 300 V DC • DC standard control circuit type with 24 V DC control circuit voltage • 1 NO + 1 NC auxiliary contact composition • Mounting support of rail and plate What does the utilisation category AC1 and AC3 mean for the TeSys contactors? Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions. AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution. AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units. What accessories are available? • Auxiliary contact blocks with serrated wiping action • Front mount dust tight auxiliary contact blocks • Pneumatic time delay blocks • Transient voltage surge suppressors • Interface modules and electronic timers • Mechanical latching blocks Is the TeSys D range a double break pole type contactor? Yes, the TeSys D range uses linear translation movement that provides double breaking of the poles.\u003c\/p\u003e\u003ch5\u003eTechnical data\u003c\/h5\u003e\n        \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eCharacteristic\u003c\/th\u003e\n              \u003cth\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Voltage\u003c\/td\u003e\n\u003ctd\u003e690V dc, 300V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Current\u003c\/td\u003e\n\u003ctd\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e7.5kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTeSys D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eMotor Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal State Configuration\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Configuration\u003c\/td\u003e\n\u003ctd\u003e1 NO\/1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Auxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eCage Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor Application\u003c\/td\u003e\n\u003ctd\u003eMotor Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Voltage Uc\u003c\/td\u003e\n\u003ctd\u003e24V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Current Ie\u003c\/td\u003e\n\u003ctd\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e95mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e99mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\/Approvals\u003c\/td\u003e\n\u003ctd\u003eEN, IEC, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetter World Claim\u003c\/td\u003e\n\u003ctd\u003eDesigned for Disassembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetter World Product\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole and Throw Configuration\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch5\u003eDatasheet\u003c\/h5\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.rs-online.com\/0e45\/0900766b817143c9.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLC1D123BD Datasheet\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch5\u003eManufacturer\u003c\/h5\u003e\u003cp\u003eSchneider Electric\u003c\/p\u003e\u003ch5\u003eWeight\u003c\/h5\u003e\u003cp\u003e544.000 G\u003c\/p\u003e\u003ch5\u003ePack Size\u003c\/h5\u003e\u003cp\u003e1 unit = 1 units\u003c\/p\u003e\u003ch5\u003eBase Unit of Measure\u003c\/h5\u003e\u003cp\u003ePCE\u003c\/p\u003e\u003ch5\u003eShipping\u003c\/h5\u003e\u003cp\u003eExpected availability from RS: currently unavailable\u003c\/p\u003e","brand":"RS","offers":[{"title":"Default Title","offer_id":46892629950709,"sku":"188-1214","price":134.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/3220\/3765\/files\/rs_020927b0-de50-443d-a128-e7c27e170c6a.png?v=1753895384","url":"https:\/\/shop.ems-yacht.com\/products\/schneider-electric-tesys-d-tesys-d-leistungsschutz-24-v-dc-spule-3-polig-300-v-ac-690-v-dc-12-a-7-5-kw","provider":"EMS Yachting","version":"1.0","type":"link"}