{"product_id":"rs-1113112","title":"Omron Monitoring Relay, 1 Phase, SPDT, DIN Rail, 0V ac","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\u003cp\u003eK8DT-VS Single-Phase Voltage Monitoring Relay. •\tDownsize control panels. •\tReduced wiring. •\tDetects errors in Motors and other equipment. •\tUse in either over current or under current mode. •\tFunction as an alarm. •\tSet threshold values. •\tAlarm output can be set as a relay or transistor output. •\tInput signal – Voltage, current, water level electrode and temperature (thermocouple or platinum resistance thermometer) can be input. •\tLower power consumption. •\tSide by side mounting is possible. •\tLong term contact reliability. •\tReliable in poor noise environments. •\tSlim profile 17.5 mm K8DT-VS3CD Single Phase Voltage Relay. •\tPower supply 24 V ac\/dc. •\tDetects abnormal voltages •\tUse in over voltage or under voltage mode •\tProtects you from equipment failures. •\tSPDT Contact output. •\tSingle phase. •\tPower ON lock time 1 s or 5 s (switched using DIP switch) •\tCurrent capacity 10 A (per pole) •\tInsertions 50 times. •\tSetting range – 20 to 200 V ac\/dc, 30 to 300 V ac\/dc, 60 to 600 V ac\/dc Features and Benefits. •\tAutomatic \/ Manual reset (switchable) (Manual reset turn OFF the power supply) •\tGreen LED Power (PWR) power •\tYellow LED Relay output (RY) •\tRed LED output (ALM) alarm •\tOne SPDT contact relay. Switchable between NO (normally open) and NC (normally closed) using DIP switch. •\tDIN Rail Mounted or Screw Mounted. •\tWeight 100 g •\tCase material PC, UL 94 V-0. •\tColour N1.5 •\tProtection IP20 (terminals) What is a Monitoring \/ Measuring Relay? A monitoring \/ measuring relay is a protective control device, various types are available suiting what you wish to monitor. The relays receive input signals then monitor them and then output an alarm signal when a set value is reached (alarm relays). The relays protect your equipment against over voltage and over current faults. Monitoring relays monitor AC power supplies, voltage and current, analogue signals detecting unusual activity in equipment against set alarm thresholds. Types of Monitoring Relays Available? •\tMotor protection relays •\tTemperature monitoring relays •\tWater level control relays •\tVoltage •\tCurrent\u003c\/p\u003e\u003ch5\u003eTechnical data\u003c\/h5\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMonitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Phase\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply DC Voltage\u003c\/td\u003e\n\u003ctd\u003e20.4→26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Current\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply AC Voltage\u003c\/td\u003e\n\u003ctd\u003e0V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20 V ac→600 V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e17.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\/Approvals\u003c\/td\u003e\n\u003ctd\u003eEN 60947-5-1, RoHS, UL 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eK8DT-VS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch5\u003eDatasheet\u003c\/h5\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.rs-online.com\/94e8\/0900766b81693cf8.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEnglish Datasheet\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch5\u003eWeight\u003c\/h5\u003e\u003cp\u003e112.000 G\u003c\/p\u003e\u003ch5\u003ePack Size\u003c\/h5\u003e\u003cp\u003e1 unit = 1 units\u003c\/p\u003e\u003ch5\u003eBase Unit of Measure\u003c\/h5\u003e\u003cp\u003ePCE\u003c\/p\u003e\u003ch5\u003eShipping\u003c\/h5\u003e\u003cp\u003eExpected availability from RS: currently unavailable\u003c\/p\u003e","brand":"RS","offers":[{"title":"Default Title","offer_id":46871471816949,"sku":"111-3112","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/3220\/3765\/files\/rs_86db5487-62d1-42ba-b39e-9f8abc850881.png?v=1753391878","url":"https:\/\/shop.ems-yacht.com\/products\/rs-1113112","provider":"EMS Yachting","version":"1.0","type":"link"}