{"product_id":"rs-1113094","title":"Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0.1A to 5A, 0 V ac, 0V ac","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\u003cp\u003eK8DT-AS Monitoring Motor Protection Relay. •\tDownsize control panels. •\tReduced wiring. •\tDetects errors in Motors and other equipment via current changes. •\tUse in either over current or under current mode. •\tFunction as an alarm. •\tSet threshold values. •\tAlarm output can be set as a relay or transistor output. •\tInput signal – Voltage, current, water level electrode and temperature (thermocouple or platinum resistance thermometer) can be input. •\tLower power consumption. •\tLong term contact reliability. •\tReliable in poor noise environments. •\tSlim profile 17.5 mm K8DT-AS2TD 24 VAC\/DC Model. •\tCurrent Monitoring Relay. •\tSingle phase. •\tTransistor Output. •\tPower supply 24 V ac\/dc. •\tSetting range 0.1 to 1 A ac\/dc, 0.5 to 5 A ac\/dc •\tDirect input or available current transformer. •\tIf using other current transformers Do Not exceed the overload capacity. Features and Benefits. •\tPower supply 100 to 240 V ac, 50\/60 Hz, 24 V dc •\tManual\/ Automatic reset (switchable) •\tManual reset – Turn OFF the power supply for minimum of 1 sec. •\tStart-up lock time 0 to 30 s. •\tGreen LED Power (PWR) •\tYellow LED output (OUT) •\tRed LED Relay output (ALM) •\tDIN Rail Mounted •\tWeight 100 g •\tCase material PC, UL 94 V-0. •\tColour N1.5 •\tProtection IP20 (terminals) What is a Monitoring \/ Measuring Relay? A monitoring \/ measuring relay is a protective control device, various types are available suiting what you wish to monitor. The relays receive input signals then monitor them and then output an alarm signal when a set value is reached (alarm relays). The relays protect your equipment against over voltage and over current faults. Monitoring relays monitor AC power supplies, voltage and current, analogue signals detecting unusual activity in equipment against set alarm thresholds. Types of Monitoring Relays Available? •\tMotor protection relays •\tTemperature monitoring relays •\tWater level control relays •\tVoltage •\tCurrent\u003c\/p\u003e\u003ch5\u003eTechnical data\u003c\/h5\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMonitoring Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Phase\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eSPST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Current Sensed\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Sensed\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Sensitivity\u003c\/td\u003e\n\u003ctd\u003eUndercurrent, Overcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003ePush-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Delay\u003c\/td\u003e\n\u003ctd\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply AC Voltage\u003c\/td\u003e\n\u003ctd\u003e0V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply DC Voltage\u003c\/td\u003e\n\u003ctd\u003e0 V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Current\u003c\/td\u003e\n\u003ctd\u003e0.1, 5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\/Approvals\u003c\/td\u003e\n\u003ctd\u003eUL 60947-5-1, RoHS, EN 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e17.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eK8DT-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch5\u003eDatasheet\u003c\/h5\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.rs-online.com\/9315\/0900766b81693cd5.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEnglish Datasheet\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch5\u003eWeight\u003c\/h5\u003e\u003cp\u003e101.000 G\u003c\/p\u003e\u003ch5\u003ePack Size\u003c\/h5\u003e\u003cp\u003e1 unit = 1 units\u003c\/p\u003e\u003ch5\u003eBase Unit of Measure\u003c\/h5\u003e\u003cp\u003ePCE\u003c\/p\u003e\u003ch5\u003eShipping\u003c\/h5\u003e\u003cp\u003eExpected availability from RS: currently unavailable\u003c\/p\u003e","brand":"RS","offers":[{"title":"Default Title","offer_id":46871470801141,"sku":"111-3094","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/3220\/3765\/files\/rs_e4cacb2a-cd34-45c4-9381-ba532752ae80.png?v=1753391843","url":"https:\/\/shop.ems-yacht.com\/products\/rs-1113094","provider":"EMS Yachting","version":"1.0","type":"link"}