{"product_id":"rs-1066240","title":"Omron H3DT Series DIN Rail Timer Relay, 2-Contact, 240 V dc 24V ac, 240 V ac, 0.1 s to 1200 h, 1-Function, SPDT Switch","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\u003cp\u003eOmron Single-function Timer RelayThe Omron H3DT series single-function timer relay is a compact, solid-state equipment with high precision and a wide range of programming features. It performs different delay functions like flicker off start\/flicker on start in the range of 0.1 seconds to 100 hours. It has intuitive programming that makes it easy to use and quick to configure. This solid-state timer delay relay with push-in plus technology is used for in-panel applications. There are 4 selectable rotary switches in front of the unit to select the time delay range. The slim design makes help in space-saving applications and also reduce work in control panels. The timers reduce power consumption by up to 60% to help in the reduction of heat generation in control panels. Its low cost and high performance make it ideal for a wide range of applications in process control environments.Features and BenefitsSwitch between flicker-off or flicker-on start mode Independent on and off time settings Slim design with 17.5mm width 8 timing ranges between 0.1seconds to 1.200 hour like 0.1 seconds to 1.2 second, 1 second to 12 second, 10 seconds to 120 second, 1 minute to 12 minute, 10 minutes to 120 minute, 1 hour to 12 hour, 10 hour to 120 hour, 100 hour to 1,200 hour Supply voltage range is 24VAC to 240VAC and 24VDC to 240VDC 2 change over relay output contacts of 5A Fast wiring due to push-in plus technology SPDT contact configuration DIN-rail mountingApplicationsTextiles Chemical industries Mining Irrigation Raw material handling Food and beverages Industrial process controlCertificationscULus approved UL 508 approved CSA C22.2 EN 61812-1 CCC certified LR certified EN 61812-1 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 EN 61812-1 EN 55011 class B EN 55011 class B EN 61000-3-2 EN 61000-3-3\u003c\/p\u003e\u003ch5\u003eTechnical data\u003c\/h5\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTimer Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eOffset Double Ring End, Timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Range\u003c\/td\u003e\n\u003ctd\u003e0.1 s to 1200 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Contacts\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Timer Functions\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e250V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming Adjustment\u003c\/td\u003e\n\u003ctd\u003eDial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply DC Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply AC Voltage\u003c\/td\u003e\n\u003ctd\u003e24, 240V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Current\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e17.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\/Approvals\u003c\/td\u003e\n\u003ctd\u003eRoHS, IEC 60664-1 4 kV\/2, DNV GL, CCC, EN 61812-1, cULus:UL 508\/CSA C22.2 No. 14, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eH3DT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch5\u003eDatasheet\u003c\/h5\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.rs-online.com\/62c8\/0900766b814e0e67.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch5\u003eWeight\u003c\/h5\u003e\u003cp\u003e104.000 G\u003c\/p\u003e\u003ch5\u003ePack Size\u003c\/h5\u003e\u003cp\u003e1 unit = 1 units\u003c\/p\u003e\u003ch5\u003eBase Unit of Measure\u003c\/h5\u003e\u003cp\u003ePCE\u003c\/p\u003e\u003ch5\u003eShipping\u003c\/h5\u003e\u003cp\u003eExpected availability from RS: currently unavailable\u003c\/p\u003e","brand":"RS","offers":[{"title":"Default Title","offer_id":46871089873141,"sku":"106-6240","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/3220\/3765\/files\/rs_cd7122e2-d683-4d46-aebd-1db55eb0cfa5.png?v=1753384111","url":"https:\/\/shop.ems-yacht.com\/products\/rs-1066240","provider":"EMS Yachting","version":"1.0","type":"link"}