{"product_id":"eaton-leistungsschutz-110-v-ac-50-hz-120-v-ac-60-hz-spule-3-polig-400-v-ac-32-a-3-schliesser-sicherheit","title":"Eaton DILMS Contactor, 120V ac Coil, 3-Pole, 32 A, 15 kW 110V ac, 3 NO, 400V ac","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\u003cp\u003eNumber of Auxiliary Contacts = 5\u003cbr\u003eTerminal Type = Screw Clamp\u003cbr\u003eContactor Application = Motor Control°C\u003cbr\u003eMaximum Operating Temperature = 60°C\u003cbr\u003eStandards\/Approvals = UL, IEC, CSAmm\u003cbr\u003ePole and Throw Configuration = 3P\u003cbr\u003e\u003cbr\u003eEaton DLIMS Series Safety Contactors. The DILMS series of safety contactors from Eaton offer reliable switching in safety-related device applications. As standard, all versions of the DILMS safety contactor are equipped with a top-mounted auxiliary contact, to stop tampering and prevent manual actuation this is non-detachable. For added safety, this contactor has integrated mirror contacts and interlocking opposite contacts. With a built-in inspection window placed immediately above the switch position indicator, it's easy to monitor the operating status of your control systems at all times. This contactor has a yellow cover to allow for fast and efficient identification of your safety devices. The dependable design of this contactor provides the perfect solution for the protection of your devices from manual activation. Available in four sizes the DILMS range of contactors cover a power range between 7 and 150 A. This series also features the DILAS safety relays which are available in three different coil voltages to complete your safety system. Features and Benefits. Safe status monitoring of the contactor (inspection window) manual activation is not possible Eligible to be used for Emergency-stop application with controlled start (category 4) Reliable and self-monitoring machine-control circuits Interlocking opposing contacts Mirror contacts Highlighted in yellow (RAL1004) Reliable screw terminals Top-mounted and non-detachable auxiliary contact (at the front). Typical Applications. Contactors can be used across a multitude of applications, users will commonly find these contactors being used within industrial settings such as factory automation and control, railway transportation, electrical systems, electric motor, lighting, and mechanical engineering and are a key component when safety functions and the protection of equipment and users are a requirement. Is a Safety Contactor or Safety Relay required?. When deciding whether to use a contactor or a relay for a safety circuit there are some general rules to help make the decision easier. A contactor should be used when the current is 9A or more, up to 1000 V ac and can be used for 1 or 3 phase safety applications. A relay should be used when the current is 10A or less, up to 250 V ac and usually on single-phase safety applications.\u003c\/p\u003e\u003ch5\u003eTechnical data\u003c\/h5\u003e\n        \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eCharacteristic\u003c\/th\u003e\n              \u003cth\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e120V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Voltage\u003c\/td\u003e\n\u003ctd\u003e400V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Current\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e15kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDILMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eTable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal State Configuration\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Configuration\u003c\/td\u003e\n\u003ctd\u003e2 NO\/3 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Auxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Voltage Uc\u003c\/td\u003e\n\u003ctd\u003e110V ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor Application\u003c\/td\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Current Ie\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e56mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e138mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\/Approvals\u003c\/td\u003e\n\u003ctd\u003eUL, IEC, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e85mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole and Throw Configuration\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch5\u003eDatasheet\u003c\/h5\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.rs-online.com\/7f63\/0900766b816fa8b9.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet- Eaton DILMS32-23(110V50HZ,120V60HZ)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch5\u003eManufacturer\u003c\/h5\u003e\u003cp\u003eEaton\u003c\/p\u003e\u003ch5\u003eWeight\u003c\/h5\u003e\u003cp\u003e476.000 G\u003c\/p\u003e\u003ch5\u003ePack Size\u003c\/h5\u003e\u003cp\u003e1 unit = 1 units\u003c\/p\u003e\u003ch5\u003eBase Unit of Measure\u003c\/h5\u003e\u003cp\u003ePCE\u003c\/p\u003e\u003ch5\u003eShipping\u003c\/h5\u003e\u003cp\u003e2–3 days within Germany \/ 3–6 days within EU\u003c\/p\u003e","brand":"RS","offers":[{"title":"Default Title","offer_id":46892069748981,"sku":"187-5355","price":209.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/3220\/3765\/files\/rs_0c45bf57-5168-4844-a7fe-c76c27546929.png?v=1753886759","url":"https:\/\/shop.ems-yacht.com\/products\/eaton-leistungsschutz-110-v-ac-50-hz-120-v-ac-60-hz-spule-3-polig-400-v-ac-32-a-3-schliesser-sicherheit","provider":"EMS Yachting","version":"1.0","type":"link"}